FEATURES

Digital Output Metering 3 Digit DPM
Constant Voltage / Constant Current Operation
High Stability and close Regulation +-0.01 %
Proven Reliability and Endurance


The New DIGITAL LAB Series Offers a range of Linear DC Regulated Power Supplies for use in Laboratories & Industries. Output voltage and current values are displayed on a 3 digit DPM. There are Dual output models with two independent isolated output. These output could be connected in series or parrallel to double the voltage or current. All the models operate in either constant voltage or constant current mode and are fully protected against continuous output short circuit and overload.


  DIGITAL LAB SELECTION GUIDE
 
  SINGLE OUTPUT
DC OUTPUT
DIMENSIONS
W X H X D (mm)
Models
16 V
VOLTAGE
CURRENT
0 - 16V
0- 2 A
210 x 133 x 250
C 1602
0 - 16V
0- 6 A
310 x 133 x 350
C 1606
32 V
0 - 32 V
0- 1 A
210 x 133 x 350
C 3201
0 - 32 V
0- 2 A
310 x 133 x 250
C 3202
0 - 32 V
0- 5 A
430 x 133 x 250
C 3205

 
 DIGITAL LAB SELECTION GUIDE
 
  DUAL OUTPUT
No. Of Outputs
VOLTAGE
CURRENT
DIMENSIONS
W X H X D (mm)
Models
2
0 - 32 V
0- 1 A
430 x 133 x 250
CD3201
0 - 32 V
0- 2 A
430 x 133 x 250
CD 3202
0 - 32 V
0- 3 A
430 x 177 x 280
CD3203

 
Note : Product upgradation is a continuous process, hence data include in this leaflet is subject to change without prior notice.
 APPLICATION
  • Schools
  • Engineering Colleges
  • FActories
  • Laboratories

 OTHER PRODUCTS

ON/ OFF Line UPS
Servo / AVR Stabilizer
Power Supply
Inverters
Emergency

 


 SPECIFICATIONS

Output Voltage & Current : See.-Selection Guide.

Metering : 3 digit DPM.

Meter Accuracy : ± 3 counts.

Constant Voltage Mode:

Regulation:

Line : ± 0.01% 2mV for ± 10% change in line output.

Load : ±0.01% ± 2mV for load change from zero to full load.

Ripple & Noise: 1 mV rms max. 20Hz -20MHz.

Constant Current Mode:

Regulation :

Line : ± 0.1% 250uA for ± 10% line change.

Load : ±0.1% ±250|.iAfor change in output voltage from 0 Volts to maximum output voltage.

Ripple & Noise : 0.04% rms.

Mode Indication : LED indicating for constant voltage / constant current operating mode.

Output Polarity: Floating w.r.t. ground

Overload Protection : Automatic overload and short circuit protection.

Operating Temperature: 0-50°C

Line Voltage : 230V AC ±10%, single phase 50Hz

CUSTOM CAPABILITY : SPECIAL VOLTAGE AND CUIRRENT RATINGS AVAILABLE ON REQUEST.

      DIGITAL INVERTERS - from 200 VA to 20 KVA.
      LINE-INTERACTIVE U.P.S. - from 500 VA to 4 KVA.

      ON LINE POWER CORRECTED U.P.S. - from 0.5 KVA to 500 KVA.
      VOLTAGE STABILIZER - from 0.5 KVA to 1000 KVA.
      POWER SUPPLIERS - Linear & non linear type.
 